Leading by Innovation

Suppliers Of Water Quality
Instrumentation & Bespoke
Measurement Systems For
Waste-Water Since 1990

PROAM - Chloride Monitor

Features

  • Fast response from 5 minutes
  • Two point automatic calibration
  • Automatic chemical cleaning
  • Continuous or intermittent analysis
  • No filtration to 100mg/L suspended solids
  • Telemetry outputs

Description

The ProAm Chloride Monitor is a simple, compact on-line analyser designed for continuous measurement. Other parameters include Ammonia and Nitrate. The instrument comprises a wall-mount analyser section with an integral sample pump; a controlling processor interfaced by a membrane keyboard and back lit LCD. Internal valving, controls the distribution of fluids during analysis and the automatic calibration / wash routines. Electrical connections for power supply and signals are externally made from a separate IP65 enclosure.

  • ProAm
    Low cost, single stream analyser with automatic calibration/clean routines

ProAm - Ammonia monitor, Ammonia measurement, Ammoniacal-nitrogenPRINCIPLE OF OPERATION

The ProAm analyser uses an ion selective (ISE) Chloride electrode. Sample is delivered through large diameter tubing to a glass vessel containing the electrode. The sample is also temperature regulated and sparged with air to create a flow past the sensor. The integral peristaltic sample pump can deliver sample directly from source or from a fast sample loop. A series of pinch valves are configured to control the passage of sample, calibration and cleaning fluids without introducing points of blockage thus improving reliability. Loss of sample or calibration fluid is detected by an inline sensor. For process and waste water applications, membrane filtration may be integrated to remove particulate and biology from the sample to improve measurement performance.

CONTROL AND MONITORING OPTIONS

Various options are available offering different levels of automation and communication. As standard, the instrument is supplied with an analogue output with its range determined by the selected calibration values. Four change-over contact relays (volt-free) are also available; two may be configured as limit alarms and two may be programmed to indicate various fault conditions. Alternatively, data may be transmitted to telemetry using Profibus or Modbus (other protocols are available on request). The instrument may be configured for continuous or intermittent analysis and controlled remotely using the BUS system.

Images/Media

ProAm - Ammonia monitor, Ammonia measurement, Ammoniacal-nitrogen

PRINCIPLE OF OPERATION

The ProAm analyser uses an ion selective (ISE) Chloride electrode. Sample is delivered through large diameter tubing to a glass vessel containing the electrode. The sample is also temperature regulated and sparged with air to create a flow past the sensor. The integral peristaltic sample pump can deliver sample directly from source or from a fast sample loop. A series of pinch valves are configured to control the passage of sample, calibration and cleaning fluids without introducing points of blockage thus improving reliability. Loss of sample or calibration fluid is detected by an inline sensor. For process and waste water applications, membrane filtration may be integrated to remove particulate and biology from the sample to improve measurement performance.

Typical Specifications

Measuring Range: 1.80-35,500 PPM FSD
Repeatability: +/- 5% or better
Enclosure: GRP to IP54 protection
Dimensions: Analyser 420(h) x 370(w) x 220(d) mm
Terminal Box 182(h) x 275(w) x 180(d) mm
Outputs: Analogue 4-20mA standard
  2 x process limit & 2 x utility alarms
Power supply: 110/230VAC 50/60Hz
Weight: 30 Kg

Related Downloads

PDF PROAM - ammonia monitor

The ProAm Ammonia Monitor is a simple, compact on-line analyser designed currently to accurately determine ammoniacal-nitrogen in real-time. Other parameters which include Nitrate, Chloride and Fluoride may also be configured. The instrument comprises a wall-mount analyser section with an integral sample pump; a controlling processor interfaced by a membrane keyboard and back lit LCD. Parameters include Ammonia, Nitrate, SAC, Nitrite, Ortho-Phosphate and Total Phosphate.

More information? Get in touch!

If you would like more information relating to this product or the services Pollution PPM can provide, please Contact Us.

For International enquiries, please contact one of our dealers listed on the following page - International Dealers

Related topics

Our Products

Protoc TOC Analyser 300
Protoc TL TOC Analyser
Proam Ammonia Monitor
OFD1 - Oil Film Detector
Terminator Pollution Abatement System